Specialty CEMS (GHG, Mercury, HCl, Heavy Metals, Odour)

Online HCl Gas Analysis System – GPIPL Model Z-207i Ein

Model Z-207i Ein

Z-207i Ein online flue gas analysis system using TDLAS and DOAS for continuous CO, CO2, SO2, NO and NO2 monitoring, with heat-traced gas path and automatic purge.

Download datasheet PDF file · 530 KB
  • Designed & manufactured in-house
  • Tested & calibrated to traceable national standards
  • Installation, AMC & after-sales support

Talk to our technical team: 08048057962

Overview

The Z-207i Ein is an online flue gas analysis system that uses TDLAS and DOAS principles for continuous monitoring of CO, CO2, SO2, NO and NO2.

A single-flange design, high-temperature flow measurement, heat-traced gas path and automatic purging for high-dust conditions suit it to demanding boiler and exhaust applications. Analog outputs and RS485 communication connect it to plant systems.

Key features

  • TDLAS + DOAS measurement
  • CO, CO₂, SO₂, NO, NO₂
  • Single-flange installation
  • Heat-traced gas path
  • Automatic purge for high dust
  • Analog outputs and RS485

Applications

  • Boiler flue gas monitoring
  • Exhaust monitoring
  • Denitrification (SCR/SNCR) systems

Technical specifications

TDLAS Technical Index
Principle TDLAS
Range CO: 0-1000ppm, CO2: 0~25%
Indication error ≤2%F.S.
Repeatability ≤2%F.S.
Zero drift ≤2%F.S./7d
Span drift ≤2%F.S./7d
DOAS Technical Index
Principle DOAS
Range SO2: 0~1000ppm, NO: 0~1000ppm, NO2: 0~1000ppm
Indication error ≤2%F.S.
Repeatability ≤2%F.S.
Zero drift ≤2%F.S./7d
Span drift ≤2%F.S./7d
General
Power (220±15%)VAC, 50Hz, 600W
Gas source 0.4~0.8MPa, oil-free, water-free and dust-free
Response time T90≤10s (double modules)
Analog output 5x4-20mA output (depend on gas combination)
Switch input 4xRelay output
Digital input 1xRS485 output
Ambient temperature -20℃~60℃
Ambient humidity ≤90%RH, non condensing
I need