Dust Monitor (Extractive) Z-44i Ein
Model Z-44i Ein
Z-44i Ein extractive laser forward-scattering dust monitor with heat-traced sampling, built for ultra-low dust emission monitoring in low-temperature, high-humidity flue gas.
- Designed & manufactured in-house
- Tested & calibrated to traceable national standards
- Installation, AMC & after-sales support
Talk to our technical team: 08048057962
Overview
The Z-44i Ein is an extractive online dust monitor that measures dust concentration by laser forward scattering. It is designed for low-temperature, high-humidity flue gas – such as downstream of wet desulphurisation – where in-situ dust monitors struggle.
The sample is extracted isokinetically through a parallel pitot tube and heat-traced so that moisture does not affect the reading. A large-diameter jet pump resists dust build-up and blockage, allowing long maintenance-free periods. Temperature compensation and automatic range switching keep measurements accurate at ultra-low concentrations.
Key features
- Laser forward-scattering measurement
- Extractive, isokinetic pitot-tube sampling
- Heat-traced sample path against moisture interference
- Large-diameter jet pump resists blockage
- Temperature compensation
- Automatic range switching
- OLED display; 4–20 mA and RS485 outputs
Applications
- Ultra-low dust emission monitoring
- Power plants after wet FGD
- Low-temperature, high-humidity stacks
Technical specifications
| Range | 0~20mg/m3, 0~50mg/m3 (customizable) |
|---|---|
| Detection limit | 0.05mg/m3 |
| Indication error | ±20% |
| Repeatability of indication error | ±10% |
| IP grade | IP54 |
| Power | 1500W |
| Analog output | 4x4-20mA output, max load of 500Ω |
| Communication interface | RS485, RS232 (optional) |
| Working temperature | -20℃~50℃ |
| Medium temperature | <300℃ |
| Human-computer interaction | OLED display |
| Weight | 100kg |